Manufacturer: Helukabel
Technical Data
- PVC drag chain cable, in alignment with DIN VDE 0285-525-2-51 / DIN EN 50525-2-51
- Temperature range flexible -10°C to +80°C
- fixed -40°C to +80°C
- Nominal voltage AC U0/U 300/500 V
- Test voltage core/core 4000 V
- Breakdown voltage 8000 V
- Minimum bending radius flexible 7.5x Outer-Ø
- fixed 4x Outer-Ø
Cable Structure
- Copper wire bare, extra finely stranded acc. to DIN VDE 0295 Class 6 / IEC 60228 Class 6
- Core insulation: PVC, compound type Z 7225
- Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits
- Protective conductor: starting with 3 cores
- G = with protective conductor GN-YE, in the outer layer
- x = without protective conductor (OZ)
- Cores stranded in layers with optimally matched lay lengths
- Fleece wrapping over each stranding layer
- Outer sheath: oil-resistant special PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM5)
- Sheath colour: grey (RAL 7001)
- Length marking: in metres
Properties
- resistant to: oil
- suitable for use in drag chains
- the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
- oil-resistant acc. to DIN VDE 0473-811-404 / DIN EN 60811-404 / IEC 60811-404
- certifications and approvals: EAC
Application
- A highly flexible PVC drag chain cable used for installation in dry and damp rooms, but not outdoors.
- Used for frequent lifting and bending stress in machine and tool construction, in robotics and on permanently moving machine parts.
- With free movement, without tensile stress and without forced motion control capabilities, these cables have proven their reliable performance in drag chain applications.
Notes
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
- cleanroom qualification tested on analog types; please note “cleanroom qualification” in your order
- for use in energy supply systems:
- 1) the assembly instructions must be observed
- 2) for further application parameters, please refer to the selection tables
- 3) for special applications, we recommend contacting us and using our data entry form for energy supply systems
Legal notice: Images and technical data are sourced from official Helukabel documents. All rights remain with HELUKABEL® GmbH. Specifications may change without notice; despite careful preparation, errors cannot be fully excluded.